2009 Dodge Pickup
Mileage
185,194
Service Date
6/13/2024
Services Performed
- Inspect vehicle and note body damage and lights operations (warning, indicator, exterior, interior). Test drive vehicle and check all systems including brakes, steering, engine performance, and account for visible leaks.
- Tech verified customer complaint of the A/C blowing cold at first, then blowing hot. Tech connected A/C machine and recovered 0.96 Lbs of R-134A refrigerant. Tech replaced both schraeder valves and added leak detection dye to the A/C system. Tech recharged A/C system with 1.6 Lbs of R-134A refrigerant and ran A/C system. While running the A/C system, the tech noticed the low side pressure went to a vacuum and the high side pressure went below 100 psi indicating a blockage in the A/C system. Tech recommends replacing the A/C compressor, Condenser, receiver/drier and orifice tube as well as performing an A/C system flush. Customer declined repairs for the A/C this visit.
- Tech removed and replaced both radiator hoses.
- Flush entire cooling system with flush machine, Valvoline Cleaner and conditioner. Fill system to required amount with new coolant.
Dick M. gave our service a 5 star review on 6/13/2024